Code of Federal Regulations - Title 46: Shipping (December 2005)
Permanent Link:
http://vlex.com/vid/19855906
Id. vLex: VLEX-19855906
Click here to download this article in graphic format (Acrobat Reader)
TITLE 46 - SHIPPING
CHAPTER I - COAST GUARD, DEPARTMENT OF HOMELAND SECURITYSUBCHAPTER L - OFFSHORE SUPPLY VESSELSPART 129 - ELECTRICAL INSTALLATIONSsubpart e - MISCELLANEOUS ELECTRICAL SYSTEMS129.520 - Hazardous areas. (a) No OSV that carries flammable or combustible liquid with a flashpoint of below 140 F (60 C), or carries hazardous cargoes on deck or in integral tanks, or is involved in servicing wells, may have electrical equipment installed in pump rooms, in hose-storage spaces, or within 3 meters (10 feet) of a source of vapor on a weather deck unless the equipment is explosion-proof or intrinsically safe under 111.1059 or 111.10511 of this chapter. (b) No electrical equipment may be installed in any locker used to store paint, oil, turpentine, or other flammable liquid unless the equipment is explosion-proof or intrinsically safe under 111.1059 or 111.10511 of this chapter. (c) Equipment that is explosion-proof and intrinsically safe must comply with subpart 111.105 of this chapter.